Calculation of Direct Illuminance
※Case:Circular Plate Shaped Light Source.

Keyword

Direct Illuminance,Circular Plate Shaped Light Source,Luminous intensity.

Reference

[1]:『照明ハンドブック第2版』(社団法人照明学会).

Remarks

・p=(d^2+h^2)^0.5 p1=((d-r)^2+h^2)^0.5 p2=((d+r)^2+h^2)^0.5
・Eq=π*I*r^2/(h^2+r^2).
・Ep=π*I*(4*r^2-(p1-p2)^2)/(4*p1*p2).
・Evq=π*I*h*(p1-p2)^2/d/(4*p1*p2).
・Eo=π*r^2*I*h/p1/p2/p.
・d:The distance of "P" to "Q".
・Fig1:Reference[1].

History

・2014/08/01:Layout change.
・2009/11/07:Upload.